The proof is in the data.

Extensive testing showed similar impressive results. TVOCs were reduced 99.9% and formaldehyde (HCHO) reduced to 33% of the original concentration. Both Total Particulate Matter (PM) and Respirable Particle Counts were significantly reduced during testing.

Volatile Organic Compound & Formaldehyde

Particulate Matter (PM)

Respirable Particle Count

Read the Complete Studies

Extended Care

Education

Offices

Hospitality

NAME TYPE REDUCTION TIME LOCATION MODEL DATE
TVOC Airborne >99.90% 5 days Extended Care Active HEPA+ April 2021
HCHO (formaldehyde) Airborne 67.00% 5 days Extended Care Active HEPA+ April 2021
PM 2.5/10 and RPC Airborne >99.90% 5 days Extended Care Active HEPA+ April 2021
Mold spores Airborne >99.94% 5 days Commercial Office HVAC (No 03)+ODOGard MERV13 August 2021
Bacteria counts Airborne >99.99% 5 days Commercial Office HVAC (No 03)+ODOGard MERV13 August 2021
TVOC Airborne >99.99% 5 days Commercial Office HVAC (No 03)+ODOGard MERV13 August 2021
HCHO (formaldehyde) Airborne >99.99% 5 days Commercial Office HVAC (No 03)+ODOGard MERV13 August 2021
Odor intensity Airborne >99.99% 5 days Commercial Office HVAC (No 03)+ODOGard MERV13 August 2021
Mold spores Airborne >99.00% 5 days Commercial Office HVAC (PCO/BPI/50% 03) June 2021
Mold spores Surface 66.00% 5 days Commercial Office HVAC (PCO/BPI/50% 03) June 2021
Bacteria counts Airborne NA (high RH)* 5 days Commercial Office HVAC (PCO/BPI/50% 03) June 2021
Bacteria counts Surface 75.00% 5 days Commercial Office HVAC (PCO/BPI/50% 03) June 2021
TVOC Airborne >99.00% 5 days Commercial Office HVAC (PCO/BPI/50% 03) June 2021
HCHO (formaldehyde) Airborne >99.00% 5 days Commercial Office HVAC (PCO/BPI/50% 03) June 2021
PM 2.5/10.0 Airborne 50.00% 5 days Commercial Office HVAC (PCO/BPI/50% 03) June 2021
Respirable Particle Counts Airborne 43.00% 5 days Commercial Office HVAC (PCO/BPI/50% 03) June 2021
Ozone Levels Airborne .012-.024 ppm 5 days Commercial Office HVAC (PCO/BPI/50% 03) June 2021
Mold spores Airborne >99.99% 5 days Commercial Office HVAC (PCO/BPI/No 03) June 2021
Mold spores Surface 50.00% 5 days Commercial Office HVAC (PCO/BPI/No 03) June 2021
Bacteria counts Airborne >95.00% 5 days Commercial Office HVAC (PCO/BPI/No 03) June 2021
Bacteria counts Surface 90.00% 5 days Commercial Office HVAC (PCO/BPI/No 03) June 2021
TVOC Airborne >99.00% 5 days Commercial Office HVAC (PCO/BPI/No 03) June 2021
HCHO (formaldehyde) Airborne 99.90% 5 days Commercial Office HVAC (PCO/BPI/No 03) June 2021
PM 2.5/10.0 Airborne >61.00% 5 days Commercial Office HVAC (PCO/BPI/No 03) June 2021
Respirable Particle Counts Airborne >62.00% 5 days Commercial Office HVAC (PCO/BPI/No 03) June 2021
TVOC Airborne 60.00% 5 days Commercial Nail/Hair Salon pureAir 3000+ (no O3) July 2021
HCHO (formaldehyde) Airborne 57.00% 5 days Commercial Nail/Hair Salon pureAir 3000+ (no O3) July 2021
Respirable Particle Counts Airborne 83.00% 5 days Commercial Nail/Hair Salon pureAir 3000+ (no O3) July 2021
PM 2.5 Airborne 68.00% 5 days Commercial Nail/Hair Salon pureAir 3000+ (no O3) July 2021
PM  10.0 Airborne 78.00% 5 days Commercial Nail/Hair Salon pureAir 3000+ (no O3) July 2021